FEATURES


     • OPC Compliant
     • Custom Algorithms
     • Wet Gas Algorithms
     • IEC 61131 Programming
     • AGA Gas Flow Calculations
     • Wireless Remote Operations
     • Modular and Expandable I/Os
     • Limitless Multi-User Connectivity
     • Modbus RTU/ASCII Master and Slave Firmware
     • Modular Hot-Swapable RTU with Pluggable Din Rail
     • Report on Exception, Store & Forward, Peer-to-Peer
     • Interfaces with Third-Party Instrumentation & Control Systems







 

 






SPECIFICATIONS
 GENERAL SPECIFICATIONS

 Industrial PowerPC (32 bit data bus)
 Operating System 
 Dynamic Memory (RAM)
 Program Memory (Flash)
 Retained Memory (RAM)
 I/O Expansion (up to 256)
 Datalogging Support
 IEC 61131 Programming
 High Level C
 Programming
 (optional)

Embedded Linux
16 MB - 32bit, 0 wait states
16 MB
512K (battery-backed)
RS485 or Ethernet I/O modules
Yes
Yes - ISaGRAF
Yes - LINUX Open
Source Wireless Telemetry 400MHz/
900MHz/ 2.4GHz

 PORT SPECIFICATIONS

Ethernet Port
 Connection
 Protocols

 Serial Ports
 RS485 Port A
 RS232 Port B
 RS485 Port C
 RS232 Port D

 Protocols
 (master & slave)  
 Flow Control
10/100BaseTx (auto-detecting)
RJ45 (auto-crossover)
TCP/IP, ARP, UDP, ICNP, DHCP, Modbus/TCP, and more
Up to 115,200 baud
RJ45 (TD, RD, CTS, RTS, CD, DTR, DSR, GND)
RJ45 (TD, RD, CTS, RTS, CD, DTR,DSR, GND)
Screws (485+, 485-, GND) (2-wire half-
duplex)
Screws (TD, RD, RTS, GND)
Modbus RTU/ASCII;
Many others available in LINUX
Hardware, software, RTS-party
(for radios and RS485)

 ENVIRONMENTAL SPECIFICATIONS

 Environmental
 Input Power  
 Input Current
 Temperature
 Humidity 
 Flammability
 Electrical Safety
 (IEC1010)
 EMI Emissions EN55022
 EMC Immunity
 2,3,4,6)
 Surge Withstand
 Vibration IEC68-2-6
 Hazardous Locations 
 (Class 1, Div 2, 
 Groups A,B,C,D)
 Marine & Offshore 
DIN rail or flat panel mount
10-30 VDC
42 mA @ 24 VDC (typical)
-40 to 70°C (-40 to 85°C storage)
5% to 95% RH
UL 94V-0 materials
UL 508, CSA C22.2/14; EN610101; (IEC1010)

FCC part 15, ICES-003, Class A; EN55022
EN61326-1, EN50082-1 (EN61000-4-2,3,4,6)

IEEE-472 (ANSI C37.90)
UL 1604, CSA C22.2/213,
Cenelec EN50021 Zone 2


DNV (Det Norske Veritas)

 CUSTOM FEATURES

     • An Advanced add-on software will enable the RTU to perform AGA-3 orifice
       plate or AGA-7 turbine meter flow measurement calculations up to five pipes.
       AGA-8 gas density Calculations are also performed.
     • Wet Gas Metering algorithms are executed in the RTU for calculating
       production
       rate for wet gas, dry gas, condensate and water. Wet Gas calculations
       use Venturi
       flow meter data and compositional data. These algorithms along with others
       programmed in any high level language such as C can be imported into
       the RTU.
     • An ISaGRAF PLC (Programmable Logic Controller) run time is included in
       the RTU. This open programming environment supports all five IEC 61131-3
       compliant languages.
     • 3rd party LINUX applications can be executed on its standard LINUX firmware.

ORDER INFORMATION


 Please Contact us at info@vmonitor.com

 

 

 

 

 

 

 

 

 






 



 

 

 


 

 

Coming Soon...