- Features
- Specifications
- Order Information
• OPC Compliant
• Custom Algorithms
• Wet Gas Algorithms
• IEC 61131 Programming
• AGA Gas Flow Calculations
• Wireless Remote Operations
• Modular and Expandable
I/Os
• Limitless Multi-User
Connectivity
• Modbus RTU/ASCII Master
and Slave Firmware
• Modular Hot-Swapable RTU
with Pluggable Din Rail
• Report on Exception, Store
& Forward, Peer-to-Peer
• Interfaces with Third-Party
Instrumentation & Control
Systems
| Industrial PowerPC (32 bit data bus) Operating System Dynamic Memory (RAM) Program Memory (Flash) Retained Memory (RAM) I/O Expansion (up to 256) Datalogging Support IEC 61131 Programming High Level C Programming (optional) |
Embedded Linux 16 MB - 32bit, 0 wait states 16 MB 512K (battery-backed) RS485 or Ethernet I/O modules Yes Yes - ISaGRAF Yes - LINUX Open Source Wireless Telemetry 400MHz/ 900MHz/ 2.4GHz |
PORT SPECIFICATIONS
| Ethernet Port Connection Protocols Serial Ports RS485 Port A RS232 Port B RS485 Port C RS232 Port D Protocols (master & slave) Flow Control |
10/100BaseTx (auto-detecting) RJ45 (auto-crossover) TCP/IP, ARP, UDP, ICNP, DHCP, Modbus/TCP, and more Up to 115,200 baud RJ45 (TD, RD, CTS, RTS, CD, DTR, DSR, GND) RJ45 (TD, RD, CTS, RTS, CD, DTR,DSR, GND) Screws (485+, 485-, GND) (2-wire half- duplex) Screws (TD, RD, RTS, GND) Modbus RTU/ASCII; Many others available in LINUX Hardware, software, RTS-party (for radios and RS485) |
ENVIRONMENTAL SPECIFICATIONS
| Environmental Input Power Input Current Temperature Humidity Flammability Electrical Safety (IEC1010) EMI Emissions EN55022 EMC Immunity 2,3,4,6) Surge Withstand Vibration IEC68-2-6 Hazardous Locations (Class 1, Div 2, Groups A,B,C,D) Marine & Offshore |
DIN rail or flat panel mount 10-30 VDC 42 mA @ 24 VDC (typical) -40 to 70°C (-40 to 85°C storage) 5% to 95% RH UL 94V-0 materials UL 508, CSA C22.2/14; EN610101; (IEC1010) FCC part 15, ICES-003, Class A; EN55022 EN61326-1, EN50082-1 (EN61000-4-2,3,4,6) IEEE-472 (ANSI C37.90) UL 1604, CSA C22.2/213, Cenelec EN50021 Zone 2 DNV (Det Norske Veritas) |
CUSTOM FEATURES
• An Advanced add-on software will enable the RTU to perform AGA-3 orifice
plate or AGA-7 turbine meter flow measurement calculations up to five pipes.
AGA-8 gas density Calculations are also performed.
• Wet Gas Metering algorithms are executed in the RTU for calculating
production
rate for wet gas, dry gas, condensate and water. Wet Gas calculations
use Venturi
flow meter data and compositional data. These algorithms along with others
programmed in any high level language such as C can be imported into
the RTU.
• An ISaGRAF PLC (Programmable Logic Controller) run time is included in
the RTU. This open programming environment supports all five IEC 61131-3
compliant languages.
• 3rd party LINUX applications can be executed on its standard LINUX firmware.
Please Contact us at info@vmonitor.com