Well Head Monitoring

     















  • Features
  • Specifications
  • Order Information
FEATURES


     • Monitors 3 Pressure
        - Casing Head Pressure 
        - Tubing Head Pressure
        - Flowline Pressure
     • Monitors one Temperature
        - Flowline Temperature
     • Report by exception
     • Battery level indicator
     • Remote configuration
     • Long range with built-in 128 bit encryption
     • Partial AGA3 implementation for Gas Flow
     • Min/Max and percent change alarms
     • Selectable wake-up interval from 1 second to 18 hours
     • Selectable data reporting (Raw Data & Engineering Units)
     • Diagnostic data (response time, message count and signal strength)
     • IP56 enclosure suitable for marine environment

 

 

 

 



SPECIFICATIONS
 SYSTEM HARDWARE

    I/O Interface

     • 6 A/D channels -12 bit resolution (0-5 VDC or 4-20 mA)
     • 2 Opto-Isolated Digital Input Channels (3-24 VAC 0r DC)
     • Independent A/D Channel used for battery voltage level
     • Independent A/D channel used for temperature
     • Independent A/D channel used for RTU
     • 1 Digital channel monitors the status of a digital switch; used for tank
       monitoring & detecting alarms.
     • 1 D/A channels -12 bit resolution –current (4-20 mA) & voltage (0-5) outputs

    Processor and Memory

     • 8051 Micro-Controller running at 12.58MHz with 64KB Data Memory

    Serial Ports

     • 1 RS232 interface port with baud up to 115,200 bps
 
 WIRELESS

     • Type (Standard) 2.4 GHz (50mW or 100mW) : DSSS (direct Sequence Spread        Spectrum) Line of sight 2.2 Km
     • (0ptional) 900 MHz (100mW or 1W): ISM, FSK, FHSS (Frequency Hopping Spread        Spectrum) Line of sight 10 Km

 POWER

     • Input Range 6.0 -15.0 VDC
     • Low Power Operating Mode with power consumption <10 mA without radio
     • Optional Battery operated or Continuous power with Solar Panel

 SOFTWARE DETAILS

    Operation Modes

     • Sleep Mode (Battery Operated)
     • Continuous (Power)
     • Stand Alone

    Timer/Clock

     • On-board
     • Wake up timer adjustable from 1 sec. to 255 hours

    Communication Protocols

     • vMBus Communications Protocol/HART Protocol
     • MODBUS Protocol Support

    Firmware

     • Data Totalizer, Pulse Counter/Accumulator, Square Root Extraction,
       Engineering Units, Conversion/Scaling, PID, Alarms, Valve Control,
       Remote Configuration

 MECHANICAL SPECIFICATIONS

    Operating Temperature

     • -40°C to +85˚C (-40 ˚F to + 185˚F)
     • Humidity Range 5-90% non-condensing

    General Dimensions

     • 14" x 14" x 6" (W x H xD)

    Housing

     • Nema 4X SS315
ORDER INFORMATION


  Please Contact us at info@vmonitor.com

 

 

 

 

 

 













 

 