- Features
- Specifications
- Order Information
• Stainless Steel Enclosure
• Local Control Panel with optional HMI display
• Open Controller with the power of open Linux
• Advanced programming capabilities
• Redundant networks
• Long range Transceivers 5 km
Frequency Range
• Optimization for Gas Lifted and Water Injection Wells
• Can be customized for different Artificial Lift methods
• Diverse Power options : 12VDC, Battery -7Day autonomy
• All flow calculations as per AGA3 & AGA8
• Gas Injection Control (Local/Remote)
• Remote well shut in or by contingency
• Continuous remote monitoring of operation
• Monitor Process Variables with High Accuracy instrumentation ( 0.025%)
- Casing
- Head temperature
- Inlet gas lift pressure
- Tubing-head pressure
- Casing head pressure
- Tubing-head Temperature
- Well outlet discharge pressure.
- Nozzle outlet differential pressure
- Gas lift injection differential pressure
• Optional Meter Run with
- Flow control valve
- Pressure, DP and Temperature sensing elements insertion points
- System Bypass valve
- Complete Hydro Tested for various pressure range
• RTU with 512K X *RAM for data.With the large memory allows minimum
32,000 historical inputs with time and date stamps can be stored.
• One modem port and one RS-232C serial port.
• Internal Inputs for internal Temperatures, Four pulse inputs
• Five multy purpose , memory-mapped digital i/o lines,
• Six general purpose analog inputs
• Two 12-bit RTD inputs
• Local Control Panel
BASE UNIT
32-Bit Power PC with power to grow
Support for 50,000+ distributed I/O
ISaGRAF IEC61131-3 programming
Datalogging and I/O transfers
Redundant Datalogging and Datalog Server
Modbus/TCP, ASCII and RTU
Local Control panel with HMI
WIRELESS COMMUNICATION
Long range Transceivers 5 km Frequency Range
2.4 GHZ, 900Mhz, 400Mhz
Optional GPRS
MECHANICAL SPECIFICATIONS
Operating Temperature
• -40°C to +85˚C (-40 ˚F to + 185˚F) with option of -40˚C to +125˚C
• Humidity Range 5-90% non-condensing
Mounting Type
• Iron Stand
Enclosure Type
• Stainless Steel Enclosure with intrude sensors
OPTIONAL SOLAR SYSTEM
| Two Solar Modules Maximum Power (Pmax) Maximum Power Voltage (Vmpp) Maximum Power Current (Impp) Open Circuit Voltage (Voc) Short Circuit Current (Isc) Max System Voltage Temperature Coefficient of Voc Temperature Coefficient of Isc Controller Rated Solar Input Rated Load 6/10/20 A 25% Current Overload Regulation Voltage Sealed Battery Load Disconnect LVD Reconnect Temp. Comp. (mV/°C) |
87W (+10%/-5%) 17.4VDC 5.02A 21.7 5.34A 600V -8.21/10^2 V/°C 2.12x10^3 A/°C 12V 24V 6.5/10/20 A Rated Load 6/10/20 A 5 min. 5 min. 14.1 V 28.2 V 11.5 V 23.0 V V 25.2 V -28 -26 |
Please Contact us at info@vmonitor.com